Warehouse of Quality

Winder Stair Requirements Explained Building Code Trainer

Winder Stair Requirements Explained Building Code Trainer
Winder Stair Requirements Explained Building Code Trainer

Winder Stair Requirements Explained Building Code Trainer To understand if a winder tread is code compliant, we need to take a look at code section r311.7.5.2.1 within the 2018 international residential code (irc) to see what those requirements are. please note that in this post we will be looking at the code standards related to residential winder stairs in accordance with the international. In spiral stairways, the minimum winder tread depth at the walking is reduced to 6.75 inches at the walkline. the maximum riser height is 9.5 inches and the minimum clear width is 26 inches for spiral stairs. and finally, curved stairways must comply with the ibc 1011.5.2 requirements, plus the inner radius of the stair must be at least twice.

Winder Stair Requirements Explained Building Code Trainer
Winder Stair Requirements Explained Building Code Trainer

Winder Stair Requirements Explained Building Code Trainer Therefore let us recap on the residential stair code requirements: minimum 36 inch clear width for stairway. maximum 4 1 2 inch handrail projection into stairway width, on either side. minimum 6′ 8″ headroom height clearance for stairway. maximum 12′ 7″ vertical height (rise) for a flight of stairs. maximum 7 3 4 inch stair riser height. The width of each landing shall not be less than the width of the stairway served. every landing shall have a minimum dimension of 36 inches (914 mm) measured in the direction of travel. r311.3 floors and landings at exterior doors. there shall be a landing or floor on each side of each exterior door. Building codes mandate stairs should be at least 36 inches wide. this width is great for three winders to make a turn of 90 degrees. this means each winder stair creates a 30 degree angle. the center of the winder tread is always going to be greater than 10 inches if the stairs are 36 inches wide. this is plenty safe. Generally, the minimum stair width is 44 inches, unless the stairway serves an occupant load of less than 50, in which case the minimum width is 36 inches. note that if the stairway is serving as an accessible means of egress, the minimum width between handrails is 48 inches, unless the building is fully sprinkler protected or the stairway is.

How To Winder Stairs
How To Winder Stairs

How To Winder Stairs Building codes mandate stairs should be at least 36 inches wide. this width is great for three winders to make a turn of 90 degrees. this means each winder stair creates a 30 degree angle. the center of the winder tread is always going to be greater than 10 inches if the stairs are 36 inches wide. this is plenty safe. Generally, the minimum stair width is 44 inches, unless the stairway serves an occupant load of less than 50, in which case the minimum width is 36 inches. note that if the stairway is serving as an accessible means of egress, the minimum width between handrails is 48 inches, unless the building is fully sprinkler protected or the stairway is. Although this type of stair system might be difficult to use or even move furniture around, it is allowed under the international residential code. therefore to understand if a spiral staircase is compliant, let us take a look at code section r311.7.10.1 within the 2018 international residential code (irc). The winders are the three steps that turn the direction of travel by 90º. due to the nature of the code requirements that govern them, it is necessary to have a 45º flat spot that is 6″ long on the inside part of where the two walls meet. without this, it is impossible to achieve satisfaction for the building codes.

Comments are closed.