R22 Refrigerant Pressure Chart
R22 Pressure Temp Chart Physical properties of r22. in parallel to using the r22 pt chart, professionals will usually need to know some of the following r22 physical properties: r22 liquid density at 69°c: 1.49 g cm 3. r22 gas density at 15°c: 3.66 kg m 3. triple point temperature: 115.76k. critical pressure: 49.36 bar. heat capacity ratio at 86°f: 1.178253. R 22 refrigerant pressure temperature chart & table downloads. r22 pressure temperature chart [pdf] igas, 8105 anderson road, tampa, fl 33634 usa, a supplier of refrigerant gases, web: igasusa tel: 813 443 0757 gives pressure and temperatures in both f & c for r22 from 49°f ( 5.4 psig) up to 150°f (381.7 psig).
R22 Freon Pressure Chart R22 pressure temperature chart 49 45: 1 17.2 51: 10.6 101: 38.3 48 44.4 2 saturation pressure temperature data for r22 (psig)* temp (°f) pressure temp (°c) temp. This pdf file shows the data points for r 22, r 410a, r 407c, r 134a and r 404a refrigerants based on available information. it is updated by advantage engineering, inc., a company that provides engineering services and products. Temperature and pressure chart for refrigerants r22, r410a, r12, r134a, r401a, r409a, r502, r404a, r507a, r408a and r402a. engineering toolbox resources, tools and basic information for engineering and design of technical applications!. Refrigerant pressure temperature chart pt chart for r 410a, r 134a, and r 22. these are currently the three most widely used refrigerants on the market today for hvac applications in residential and commercial use. r 22 refrigerant is the king and used widely in the residential and commercial markets followed by r 134a which is used in.
R22 Refrigerant Chart Premium Temperature Pressure Chart R 134a R407c R Temperature and pressure chart for refrigerants r22, r410a, r12, r134a, r401a, r409a, r502, r404a, r507a, r408a and r402a. engineering toolbox resources, tools and basic information for engineering and design of technical applications!. Refrigerant pressure temperature chart pt chart for r 410a, r 134a, and r 22. these are currently the three most widely used refrigerants on the market today for hvac applications in residential and commercial use. r 22 refrigerant is the king and used widely in the residential and commercial markets followed by r 134a which is used in. Critical pressure (psia) 723.7 critical temperature (°f) 205.1 critical density (lb. ft^ 3) 32.7 vapor density (bp,lb. ft^ 3) 0.294 heat of vaporization (bp,btu lb.) 100.5 global warming potential (co2 = 1.0) 1810 ashrae standard 34 safety rating a1 refrigerant boiling point physical properties refrigerant 80°f 40°f 0°f 40°f 80°f 120°f. Using the formulas provided: condensing temperature = 35°c 10°c = 45°c. evaporation temperature = 27°c – 20°c = 7°c. these calculations serve as rough estimates. to ascertain the operational pressures of the compressor: for r22 refrigerant: high pressure is approximately 1.75 mpa. low pressure is approximately 0.6 mpa.
Comments are closed.