Gas Valve Amp Test Youtube

Gas Valve Amp Test Youtube
Gas Valve Amp Test Youtube

Gas Valve Amp Test Youtube I will be checking various gas valves to see if you can check the continuity of the solenoid with an ohmmeter. some gas valves cannot be checked with an ohm. This one shows how to do a voltmeter check of the gas valve. this video is part of the heating and cooling series of training videos made to accompany my we.

Gas Valve Test Sgv100 Youtube
Gas Valve Test Sgv100 Youtube

Gas Valve Test Sgv100 Youtube Supercoolsliderule this video tutorial teaches how to test a gas valved on a gas furnace. Pull the wires off the gas valve terminals. each wire is connected to a push on clip that slides off the terminal. write down where the wires connect to the valve so you can reattach them later. step 4. turn the test control on the multimeter to "mv," which stands for millivolt. step 5. hold each tester wand on the multimeter to one of the. Igniter safety valve circuit test. take a clamp on type ammeter, and attach it to the circuit to determine whether the igniter is working efficiently enough to open the safety valve. clamp your meter onto the wire that either goes to the bake burner igniter or the bake burner safety valve. turn on the bake function, and see what current is. Disassemble and inspect the gas valve. to gain access to the gas valve, start by removing the front panel of your furnace. once exposed, locate the pilot light assembly and disconnect it from the gas valve. next, use a wrench or pliers to loosen and remove any nuts or bolts securing the gas valve in place.

Gas Training Testing A Gas Valve In 60 Seconds Ex Ideal Boilers
Gas Training Testing A Gas Valve In 60 Seconds Ex Ideal Boilers

Gas Training Testing A Gas Valve In 60 Seconds Ex Ideal Boilers Igniter safety valve circuit test. take a clamp on type ammeter, and attach it to the circuit to determine whether the igniter is working efficiently enough to open the safety valve. clamp your meter onto the wire that either goes to the bake burner igniter or the bake burner safety valve. turn on the bake function, and see what current is. Disassemble and inspect the gas valve. to gain access to the gas valve, start by removing the front panel of your furnace. once exposed, locate the pilot light assembly and disconnect it from the gas valve. next, use a wrench or pliers to loosen and remove any nuts or bolts securing the gas valve in place. Test #1 – resistance test. one way to test if your main control valve is bad is by testing resistance. we can do this with our digital multimeter. first lets make sure it is in the correct setting. we what it in the ohm’s setting (ohms is basically a term that refers to resistance). this is sometimes shown in symbol form: Ω. Select the resistance ohms mode (usually shown as Ω). hook up your multimeter’s probes to the terminals on the gas valve. if the reading is ol, then the gas valve is bad. another way to test a gas valve is to hit it with a hammer. no, really by hitting your gas valve with a hammer, it can become unstuck and open up.

Comments are closed.